Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
Heart Rhythm ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604592

RESUMO

BACKGROUND: The utility of atrioventricular (AV) optimization (AVO) algorithms remains in question. A substudy of the SMART-AV trial found that patients with prolonged interventricular delays ≥70 ms were more likely to benefit from cardiac resynchronization therapy (CRT) with AVO. The SMART-CRT trial evaluated AVO on the basis of these results, but the study was underpowered. OBJECTIVE: To increase statistical power, data from SMART-AV patients meeting the inclusion criterion of interventricular delay ≥70 ms were pooled with data from SMART-CRT to reassess AVO. METHODS: SMART-CRT and SMART-AV were prospective, randomized, multicenter clinical trials. Patients in both studies were randomized to be programmed with an AVO algorithm (SmartDelay) or fixed AV delay (120 ms). Paired echocardiograms obtained at baseline and 6 months were compared, with CRT response defined as ≥15% reduction in left ventricular end-systolic volume. RESULTS: A total of 451 complete patient data sets were pooled and analyzed. The baseline demographics between studies did not differ statistically in terms of age, sex, left ventricular ejection fraction, or left ventricular end-systolic volume. The AVO group had a greater proportion of CRT responders (SmartDelay, 73.9%; fixed, 63.1%; P = .014) and greater changes in measures of reverse remodeling. SmartDelay patients with a recommended sensed AV delay outside the nominal range (100-120 ms) had 2.3 greater odds of CRT response than fixed AV delay patients. CONCLUSION: Greater CRT response and measures of reverse remodeling were observed in patients with SmartDelay enabled vs a fixed AV delay. This study supports the use of SmartDelay in patients with a CRT indication and interventricular delay ≥70 ms. GOV REGISTRATION: NCT00677014 and NCT03089281.

2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305503

RESUMO

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Veias Pulmonares/cirurgia , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Método Simples-Cego , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia
3.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37634148

RESUMO

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/classificação , Fibrilação Atrial/cirurgia , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva , Método Simples-Cego , Taquicardia/etiologia , Resultado do Tratamento
4.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

6.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183700

RESUMO

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia
7.
Patient ; 16(4): 359-369, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37076697

RESUMO

BACKGROUND: The statistical significance of clinical trial outcomes is generally interpreted quantitatively according to the same threshold of 2.5% (in one-sided tests) to control the false-positive rate or type I error, regardless of the burden of disease or patient preferences. The clinical significance of trial outcomes-including patient preferences-are also considered, but through qualitative means that may be challenging to reconcile with the statistical evidence. OBJECTIVE: We aimed to apply Bayesian decision analysis to heart failure device studies to choose an optimal significance threshold that maximizes the expected utility to patients across both the null and alternative hypotheses, thereby allowing clinical significance to be incorporated into statistical decisions either in the trial design stage or in the post-trial interpretation stage. In this context, utility is a measure of how much well-being the approval decision for the treatment provides to the patient. METHODS: We use the results from a discrete-choice experiment study focusing on heart failure patients' preferences, questioning respondents about their willingness to accept therapeutic risks in exchange for quantifiable benefits with alternative hypothetical medical device performance characteristics. These benefit-risk trade-off data allow us to estimate the loss in utility-from the patient perspective-of a false-positive or false-negative pivotal trial result. We compute the Bayesian decision analysis-optimal statistical significance threshold that maximizes the expected utility to heart failure patients for a hypothetical two-arm, fixed-sample, randomized controlled trial. An interactive Excel-based tool is provided that illustrates how the optimal statistical significance threshold changes as a function of patients' preferences for varying rates of false positives and false negatives, and as a function of assumed key parameters. RESULTS: In our baseline analysis, the Bayesian decision analysis-optimal significance threshold for a hypothetical two-arm randomized controlled trial with a fixed sample size of 600 patients per arm was 3.2%, with a statistical power of 83.2%. This result reflects the willingness of heart failure patients to bear additional risks of the investigational device in exchange for its probable benefits. However, for increased device-associated risks and for risk-averse subclasses of heart failure patients, Bayesian decision analysis-optimal significance thresholds may be smaller than 2.5%. CONCLUSIONS: A Bayesian decision analysis is a systematic, transparent, and repeatable process for combining clinical and statistical significance, explicitly incorporating burden of disease and patient preferences into the regulatory decision-making process.


Assuntos
Insuficiência Cardíaca , Humanos , Teorema de Bayes , Ensaios Clínicos como Assunto , Insuficiência Cardíaca/terapia , Técnicas de Apoio para a Decisão , Assistência Centrada no Paciente
8.
Cardiovasc Digit Health J ; 3(5): 247-255, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35942055

RESUMO

Background: Cardiac implantable electronic devices (CIEDs) may enable early identification of COVID-19 to facilitate timelier intervention. Objective: To characterize early physiologic changes associated with the onset of acute COVID-19 infection, as well as during and after acute infection, among patients with CIEDs. Methods: CIED sensor data from March 2020 to February 2021 from 286 patients with a CIED were linked to clinical data from electronic health records. Three cohorts were created: known COVID-positive (n = 20), known COVID-negative (n = 166), and a COVID-untested control group (n = 100) included to account for testing bias. Associations between changes in CIED sensors from baseline (including HeartLogic index, a composite index predicting worsening heart failure) and COVID-19 status were evaluated using logistic regression models, Wilcoxon signed rank tests, and Mann-Whitney U tests. Results: Significant differences existed between the cohorts by race, ethnicity, CIED device type, and medical admissions. Several sensors changed earlier for COVID-positive vs COVID-negative patients: HeartLogic index (mean 16.4 vs 9.2 days [P = .08]), respiratory rate (mean 8.5 vs 3.9 days [P = .01], and activity (mean 8.2 vs 3.5 days [P = .008]). Respiratory rate during the 7 days before testing significantly predicted a positive vs negative COVID-19 test, adjusting for age, sex, race, and device type (odds ratio 2.31 [95% confidence interval 1.33-5.13]). Conclusion: Physiologic data from CIEDs could signal early signs of infection that precede clinical symptoms, which may be used to support early detection of infection to prevent decompensation in this at-risk population.

9.
J Card Fail ; 28(8): 1245-1254, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35460884

RESUMO

BACKGROUND: Patients with heart failure (HF) and reduced ejection fraction suffer from a relapsing and remitting disease course, where early treatment changes may improve outcomes. We assessed the clinical integration and safety of the HeartLogic multisensor index and alerts in HF care. METHODS: The Multiple cArdiac seNsors for mAnaGEment of Heart Failure (MANAGE-HF) study enrolled 200 patients with HF and reduced ejection fraction (<35%), New York Heart Association functional class II-III symptoms, implanted with a cardiac resynchronization therapy-defibrillator or and implantable cardioverter defibrillator, who had either a hospitalization for HF within 12 months or unscheduled visit for HF exacerbation within 90 days or an elevated natriuretic peptide concentration (brain natriuretic peptide [BNP] of ≥150 pg/mL or N-terminal pro-BNP [NT-proBNP] of ≥600 pg/mL). This phase included the development of an alert management guide and evaluated changes in medical treatment, natriuretic peptide levels, and safety. RESULTS: The mean age of participants was 67 years, 68% were men, 81% were White, and 61% had a HF hospitalization in prior 12 months. During follow-up, there were 585 alert cases with an average of 1.76 alert cases per patient-year. HF medications were augmented during 74% of the alert cases. HF treatment augmentation within 2 weeks from an initial alert was associated with more rapid recovery of the HeartLogic Index. Five serious adverse events (0.015 per patient-year) occurred in relation to alert-prompted medication change. NTproBNP levels decreased from median of 1316 pg/mL at baseline to 743 pg/mL at 12 months (P < .001). CONCLUSIONS: HeartLogic alert management was safely implemented in HF care and may optimize HF management. This phase supports further evaluation in larger studies. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03237858).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Algoritmos , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Masculino , Peptídeo Natriurético Encefálico/uso terapêutico , Fragmentos de Peptídeos , Volume Sistólico
10.
JAMA Cardiol ; 7(5): 540-548, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35319725

RESUMO

Importance: Despite bearing a disproportionate burden of heart failure (HF), Black and Hispanic individuals have been poorly represented in HF clinical trials. Underrepresentation in clinical trials limits the generalizability of the findings to these populations and may even introduce uncertainties and hesitancy when translating trial data to the care of people from underrepresented groups. The Heart Failure Collaboratory, a consortium of stakeholders convened to enhance HF therapeutic development, has been dedicated to improving recruitment strategies for patients from diverse and historically underrepresented groups. Observations: Despite federal policies from the US Food and Drug Administration and National Institutes of Health aimed at improving trial representation, gaps in trial enrollment proportionate to the racial and ethnic composition of the HF population have persisted. Increasing trial globalization with limited US enrollment is a major driver of these patterns. Additional barriers to representative enrollment include inequities in care access, logistical issues in participation, restrictive enrollment criteria, and English language requirements. Conclusions and Relevance: Strategies for improving diverse trial enrollment include methodical study design and site selection, diversification of research leadership and staff, broadening of eligibility criteria, community and patient engagement, and broad stakeholder commitment. In contemporary HF trials, diverse trial enrollment is not only feasible but can be efficiently achieved to improve the generalizability and translation of trial knowledge to clinical practice.


Assuntos
Etnicidade , Insuficiência Cardíaca , População Negra , Insuficiência Cardíaca/terapia , Humanos , Seleção de Pacientes , Grupos Raciais
11.
Circ Heart Fail ; 15(1): e008797, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937393

RESUMO

BACKGROUND: Regulatory and clinical decisions involving health technologies require judgements about relative importance of their expected benefits and risks. We sought to quantify heart-failure patients' acceptance of therapeutic risks in exchange for improved effectiveness with implantable devices. METHODS: Individuals with heart failure recruited from a national web panel or academic medical center completed a web-based discrete-choice experiment survey in which they were randomized to one of 40 blocks of 8 experimentally controlled choice questions comprised of 2 device scenarios and a no-device scenario. Device scenarios offered an additional year of physical functioning equivalent to New York Heart Association class III or a year with improved (ie, class II) symptoms, or both, with 30-day mortality risks ranging from 0% to 15%, in-hospital complication risks ranging from 0% to 40%, and a remote adjustment device feature. Logit-based regression models fit participants' choices as a function of health outcomes, risks and remote adjustment. RESULTS: Latent-class analysis of 613 participants (mean age, 65; 49% female) revealed that two-thirds were best represented by a pro-device, more risk-tolerant class, accepting up to 9% (95% CI, 7%-11%) absolute risk of device-associated mortality for a one-year gain in improved functioning (New York Heart Association class II). Approximately 20% were best represented by a less risk-tolerant class, accepting a maximum device-associated mortality risk of 3% (95% CI, 1%-4%) for the same benefit. The remaining class had strong antidevice preferences, thus maximum-acceptable risk was not calculated. CONCLUSIONS: Quantitative evidence on benefit-risk tradeoffs for implantable heart-failure device profiles may facilitate incorporating patients' views during product development, regulatory decision-making, and clinical practice.


Assuntos
Comportamento de Escolha/fisiologia , Insuficiência Cardíaca/fisiopatologia , Preferência do Paciente/estatística & dados numéricos , Adulto , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Risco , Medição de Risco , Inquéritos e Questionários/estatística & dados numéricos
14.
Curr Neurol Neurosci Rep ; 21(12): 72, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34817719

RESUMO

PURPOSE OF REVIEW: Concussion is a complex injury that may present as a variety of clinical profiles, which can overlap and reinforce one another. This review summarizes the medical management of patients with concussion and persistent post-concussive symptoms (PPCS). RECENT FINDINGS: Management of concussion and PPCS relies on identifying underlying symptom generators. Treatment options include sub-symptom threshold aerobic exercise, cervical physical therapy, vestibular therapy, vision therapy, cognitive rehabilitation, cognitive behavioral therapy, pharmacological management, or a combination of treatments. Evidence-based treatments have emerged to treat post-concussion symptom generators for sport-related concussion and for patients with PPCS.


Assuntos
Concussão Encefálica , Terapia Cognitivo-Comportamental , Síndrome Pós-Concussão , Concussão Encefálica/terapia , Exercício Físico , Humanos , Neurologistas , Síndrome Pós-Concussão/diagnóstico , Síndrome Pós-Concussão/terapia
15.
Curr Neurol Neurosci Rep ; 21(12): 70, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34817724

RESUMO

PURPOSE OF REVIEW: Concussion produces a variety of signs and symptoms. Most patients recover within 2-4 weeks, but a significant minority experiences persistent post-concussive symptoms (PPCS), some of which may be from associated cervical or persistent neurologic sub-system (e.g., vestibular) dysfunction. This review provides evidence-based information for a pertinent history and physical examination of patients with concussion. RECENT FINDINGS: The differential diagnosis of PPCS is based on the mechanism of injury, a thorough medical history and concussion-pertinent neurological and cervical physical examinations. The concussion physical examination focuses on elements of autonomic function, oculomotor and vestibular function, and the cervical spine. Abnormalities identified on physical examination can inform specific forms of rehabilitation to help speed recovery. Emerging data show that there are specific symptom generators after concussion that can be identified by a thorough history, a pertinent physical examination, and adjunct tests when indicated.


Assuntos
Concussão Encefálica , Síndrome Pós-Concussão , Concussão Encefálica/complicações , Concussão Encefálica/diagnóstico , Humanos , Neurologistas , Síndrome Pós-Concussão/diagnóstico
16.
BMJ Open ; 11(10): e049017, 2021 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-34706949

RESUMO

OBJECTIVES: There is a controversy about whether both sexes' response to cardiac resynchronisation therapy (CRT) is similar. We aimed to assess a causal effect of sex on CRT response. DESIGN: Secondary analysis of a randomised controlled trial (RCT) data. Doubly robust augmented-inverse-probability-weighted (AIPW) estimation of sex effect on CRT response. SETTING: The SmartDelay Determined Atrioventricular (AV) Optimisation (SMART-AV) RCT. PARTICIPANTS: The SMART-AV RCT enrolled New York Heart Association class III-IV patients with heart failure (HF) with left ventricular ejection fraction (LVEF) ≤35% despite optimal medical therapy and QRS duration ≥120 ms, in sinus rhythm. After exclusion of those with missing outcome or covariates, 741 participants (age 66±11 years; 33% female; 78% white; LVEF 28%±9%; 58% ischaemic cardiomyopathy; 75% left bundle branch block; left ventricular end-systolic volume index (LVESVI) 65±30 mL/m2) were included. INTERVENTIONS: Implanted CRT defibrillator with randomly assigned AV delay as either (1) fixed at 120 ms, or (2) echocardiography-determined, or (3) SmartDelay algorithm-programmed. OUTCOME: A composite of freedom from death and HF hospitalisation and a >15% reduction in LVESVI at 6 month post-CRT was the endpoint. RESULTS: The primary endpoint was met by 337 patients (45.5%); 134 were women (55.6% response) and 203 were men (40.6% response); p<0.0001. After conditioning for 33 covariates that included baseline demographic, clinical, ECG, echocardiographic and biomarker characteristics, known predictors of CRT response, logistic regression showed a higher probability for composite CRT response for women versus men (OR 1.79; 95% CI 1.08 to 2.98; p<0.0001), whereas AIPW estimation showed no difference in CRT response (average treatment effect 0.88; 95% CI 0.41 to 1.89; p=0.739). After removing colliders from the model, both logistic regression (OR 1.00; 95% CI 0.69 to 1.44) and AIPW (ATE 1.06; 95% CI 0.96 to 1.16) reported similar results. CONCLUSIONS: Both sexes' response to CRT is similar. Sex differences in HF substrate, treatment and comorbidities explain sex disparities in CRT outcomes. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier; NCT00677014.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Bloqueio de Ramo/terapia , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Resultado do Tratamento
17.
JACC Clin Electrophysiol ; 7(12): 1505-1515, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34454883

RESUMO

OBJECTIVES: This study aimed to apply machine learning (ML) to develop a prediction model for short-term cardiac resynchronization therapy (CRT) response to identifying CRT candidates for early multidisciplinary CRT heart failure (HF) care. BACKGROUND: Multidisciplinary optimization of cardiac resynchronization therapy (CRT) delivery can improve long-term CRT outcomes but requires substantial staff resources. METHODS: Participants from the SMART-AV (SmartDelay-Determined AV Optimization: Comparison of AV Optimization Methods Used in Cardiac Resynchronization Therapy [CRT]) trial (n = 741; age: 66 ± 11 years; 33% female; 100% New York Heart Association HF functional class III-IV; 100% ejection fraction ≤35%) were randomly split into training/testing (80%; n = 593) and validation (20%; n = 148) samples. Baseline clinical, electrocardiographic, echocardiographic, and biomarker characteristics, and left ventricular (LV) lead position (43 variables) were included in 8 ML models (random forests, convolutional neural network, lasso, adaptive lasso, plugin lasso, elastic net, ridge, and logistic regression). A composite of freedom from death and HF hospitalization and a >15% reduction in LV end-systolic volume index at 6 months after CRT was the end point. RESULTS: The primary end point was met by 337 patients (45.5%). The adaptive lasso model was the most more accurate (area under the receiver operating characteristic curve: 0.759; 95% CI: 0.678-0.840), well calibrated, and parsimonious (19 predictors; nearly half potentially modifiable). Participants in the 5th quintile compared with those in the 1st quintile of the prediction model had 14-fold higher odds of composite CRT response (odds ratio: 14.0; 95% CI: 8.0-14.4). The model predicted CRT response with 70% accuracy, 70% sensitivity, and 70% specificity, and should be further validated in prospective studies. CONCLUSIONS: ML predicts short-term CRT response and thus may help with CRT procedure and early post-CRT care planning. (SmartDelay-Determined AV Optimization: A Comparison of AV Optimization Methods Used in Cardiac Resynchronization Therapy [CRT] [SMART-AV]; NCT00677014).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Feminino , Insuficiência Cardíaca/terapia , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
18.
Heart Rhythm ; 18(8): 1344-1351, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33887451

RESUMO

BACKGROUND: The role of cardiovascular implantable electronic device (CIED)-derived activity to predict implantable cardioverter-defibrillator (ICD) therapy or death is not known. OBJECTIVE: We aimed to assess CIED-derived activity to predict clinical outcomes. METHODS: In 1500 patients enrolled in MADIT-RIT, CIED-derived patient activity was acquired daily, then averaged for the first 30 days following randomization to predict inappropriate/appropriate therapy or death. Kaplan-Meier analysis and Cox proportional regression models were used to evaluate inappropriate/appropriate therapy, heart failure, or death by 30-day CIED-derived patient activity quintiles. RESULTS: There were 1463 patients with CIED activity data (98%). Patients in the highest quintile (Q5) of activity (more active) had the highest rate of inappropriate therapy, 21% at 2 years, as compared to 7%-11% in the other 4 quintiles (P < .001), a 1.75 times higher risk (95% confidence interval [CI]: 1.23-2.50, P = .002). However, patients in the lowest quintile of activity (Q1, 1 hour/day) had the highest risk of mortality, 15% in 2 years, as compared to Q2-3 (1-2 hours/day, 8%-7% mortality), and Q4-5 (>2 hours/day, 2%-3% mortality) (P < .001). Patients with the lowest level of activity (Q1) had a 2.02 times higher risk of mortality (95% CI: 1.21-3.38, P = .007), and they had an 82% higher risk of heart failure hospitalization (95% CI: 1.28-2.57, P = .001). CONCLUSIONS: High CIED-derived 30-day median patient activity predicted inappropriate therapy, while low patient activity predicted mortality and heart failure in ICD and cardiac resynchronization therapy with defibrillator patients enrolled in MADIT-RIT. Device-derived activity assessment could serve as a useful predictor of outcomes.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/etiologia , Taquicardia Ventricular/terapia , Idoso , Falha de Equipamento , Feminino , Saúde Global , Insuficiência Cardíaca/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Taxa de Sobrevida/tendências
19.
Orthop J Sports Med ; 9(1): 2325967120972141, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33786333

RESUMO

BACKGROUND: Rugby is the fastest growing team sport in the United States for male and female athletes. It is a contact/collision sport with an injury risk profile that includes concussions. PURPOSE: To examine the prevalence of concussions in male and female rugby players in the United States and to characterize behaviors around reporting concussions that could be a target for prevention and treatment efforts. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: An online survey distributed to active members on the USA Rugby membership list was used to examine self-reported concussions in male and female athletes. Concussion-reporting behaviors and return to play after a concussion were also explored. Statistical analysis was used to compare male with female athletes and report differences, with years of experience as a dependent variable. RESULTS: The proportion of athletes with a history of at least 1 concussion was 61.9% in all respondents. Of those who reported a concussion, 50.8% reported the concussion during the game or practice in which it occurred, and 57.6% reported at least 1 concussion to a qualified medical provider. Overall, 27.7% of participants who reported ≥1 rugby-related concussion in our survey noted that at least 1 of these concussions was not formally reported. The most commonly cited reasons for not reporting a concussion included not thinking that it was a serious injury, not knowing that it was a concussion at the time, and not wanting to be pulled out of the game or practice. Additionally, 61.0% of athletes did not engage in recommended return-to-play protocols after their most recent rugby-related concussion. CONCLUSION: US rugby union athletes may not report concussions to medical personnel or follow return-to-play protocols guided by medical advice. This could result from a lack of education on concussion recognition and the risks associated with continued play after a concussion as well as limited access to health care. Further education efforts focusing on the identification of concussions, removal from play, and return-to-play protocols are necessary in the US rugby union population.

20.
Europace ; 23(3): 329-344, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33555020

RESUMO

AIMS: The risk of developing atrial fibrillation (AF) and its complications continues to increase, despite good progress in preventing AF-related strokes. METHODS AND RESULTS: This article summarizes the outcomes of the 7th Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA) held in Lisbon in March 2019. Sixty-five international AF specialists met to present new data and find consensus on pressing issues in AF prevention, management and future research to improve care for patients with AF and prevent AF-related complications. This article is the main outcome of an interactive, iterative discussion between breakout specialist groups and the meeting plenary. AF patients have dynamic risk profiles requiring repeated assessment and risk-based therapy stratification to optimize quality of care. Interrogation of deeply phenotyped datasets with outcomes will lead to a better understanding of the cardiac and systemic effects of AF, interacting with comorbidities and predisposing factors, enabling stratified therapy. New proposals include an algorithm for the acute management of patients with AF and heart failure, a call for a refined, data-driven assessment of stroke risk, suggestions for anticoagulation use in special populations, and a call for rhythm control therapy selection based on risk of AF recurrence. CONCLUSION: The remaining morbidity and mortality in patients with AF needs better characterization. Likely drivers of the remaining AF-related problems are AF burden, potentially treatable by rhythm control therapy, and concomitant conditions, potentially treatable by treating these conditions. Identifying the drivers of AF-related complications holds promise for stratified therapy.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Consenso , Humanos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...